Reverse osmosis Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.Anti-spam check. Do not fill this in! ===Power consumption for a disc tube module system=== [[File:Disc tube module and Spiral wound module.png|alt=Disc tube module and Spiral wound module|thumb|Disc tube module with RO membrane cushion and Spiral wound module with RO membrane]] {| class="wikitable" ! colspan="4" |Energy consumption per m<sup>3</sup> leachate |- |name of module |1-stage up to 75 bar |2-stage up to 75 bar |3-stage up to 120 bar |- |disc tube module |6.1β8.1 kWh/m<sup>3</sup> |8.1β9.8 kWh/m<sup>3</sup> |11.2β14.3 kWh/m<sup>3</sup> |} Summary: Please note that all contributions to Christianpedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here. You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Christianpedia:Copyrights for details). Do not submit copyrighted work without permission! Cancel Editing help (opens in new window) Discuss this page